uPVC Screens, Casings & End Caps

With the advent of appropriate technology in the form of drilling rigs, submersible pumps and motors as well as casings and screens, open water wells even in developing countries are rapidly becoming a thing of the past. Evaporation of water and the environmental hazards posed by open waterwells through contamination and the use of dry wells as dumping sites of various pollutants have been significantly minimized with the development of closed borewells.
Steel casings and screens were commonly accepted during the early years of borewells, but after prolonged use of steel casing and screen in borewells, several doubts relating to quality of water, performance, efficiency and restricted life span of the wells began to surface.

Description

PropertiesUnitsTesting SpecificationSpecified MethodValue
Long term Creep Pressure
For 1000 hours
N/mm²DIN 53795DIN 806110
Impact Resistance
(Confidence Limit) at 23±2˚C
%DIN 53453DIN 8061Min 90
Water Absorptionmg/cm²DIN 8061DIN 8061Max 4
Heat Reversion%DIN 8061DIN 8061Max 5
Densitygm/ccDIN 53479DIN 80611.4-1.45
Mean Coefficient of linear
thermal expansion in the
temperature range 0 to 70˚C
k^-1DIN 53752DIN 80610.8 x 10^-4
Thermal Conductivityw/kmDIN52612
Part 1
DIN 80610.15
Vicat Softening Temp.˚C
Part 1
ISO 2507
Part 2
ISO 2507≥79
Surface ResistanceΩ
Part 2
DIN VDE 0303DIN 8061>10^12
Yield PointN/mm²DIN EN ISO 527
Part 2
DIN 492545 to 55

Reviews